Fò lọ sí àkóónú
Vivos Ètò Iṣẹ́ Abẹ Ojú láti ọwọ́ Olcayto Guelec and David Geuder

Vivos Ètò Iṣẹ́ Abẹ Ojú láti ọwọ́ Olcayto Guelec and David Geuder jẹ́ aṣẹ́gun olókìkí púpọ̀ ti 2026 Àmì-ẹ̀yẹ Wúrà A' Design Award nínú Ẹ̀ka Ìdíje Àpẹẹrẹ Ẹ̀rọ àti Ohun-èlò Ìṣègùn.


WúràOhun-èlò Ìṣègùn· 2026

Vivos Ètò Iṣẹ́ Abẹ Ojú

látọ̀wọ́ Olcayto Guelec and David Geuder

Oníbàárà: Geuder AG

Aṣẹ́gun Àmì-ẹ̀yẹ Wúrà A' Design Award nínú Ẹ̀ka Ohun-èlò Ìṣègùn

56,783

Aṣẹ́gun Àmì Ẹ̀yẹ Tí a Jẹ́rìísí

Jẹ́rìísí Ipò Àmì Ẹ̀yẹ fún #182492

Àwọ̀

Àpẹrẹ Náà

Nípa Vivos Ètò Iṣẹ́ Abẹ Ojú

Vivos ṣàtúnṣe ibùdó iṣẹ́ abẹ gẹ́gẹ́ bí pẹpẹ tí ń dàgbà pẹ̀lú àníyàn ìṣègùn. Àwọn àtòntò mẹ́ta, Core, Nova, àti Nova+, ń mú agbára pọ̀ sí i láìsí ìrọ́pò ètò, èyí nìkan ni irú àwòrán ìmúgbòòrò tí ó rí báyìí nínú iṣẹ́ abẹ ojú. Ojú ìbáṣepọ̀ kanṣoṣo, tí a fìdí rẹ̀ múlẹ̀ ní ìdálá ìdùnnú ìlò àkọ́kọ́ ní ìdá 91.7 láìsí ìdálẹ́kọ̀ọ́ tẹ́lẹ̀, ń fi hàn àpẹrẹ tí a kọ́ yíká oníṣẹ́-abẹ dípò iṣẹ́ náà fúnra rẹ̀. Àwọn àsopọ̀ ohun èlò olùtànná, àwọn ohun èlò tí a ti mú dára àti àwọn ẹ̀kúnrẹ́rẹ́ tí a fara balẹ̀, ń fún ohun èlò náà ní ìwàláàyè tí ó dákẹ́rọ́rọ́ tí ó sì ní ìgbọ́kànlé, láìsí ariwo ojú tí ó wọ́pọ̀ nínú ẹ̀ka náà.

Ìdánimọ̀ Náà

Nípa Àmì-ẹ̀yẹ Wúrà A' Design Award

Vivos Ètò Iṣẹ́ Abẹ Ojú jẹ́ olùborí Àmì-ẹ̀yẹ Wúrà A' Design Award, ìdánimọ̀ olókìkí gan-an tí a fún àwọn àwòṣe ìpele àkọ́kọ́, tó jẹ́ ìyanu tó sì yàtọ̀. Àwọn olùborí Wúrà jẹ́ àwọn ẹ̀dá tó ní ìmúṣẹ̀dá tuntun gidigidi, tó ní ojú-ìwòye tó jìnnà tó sì ń tàn yòò tí wọ́n ń ṣàfihàn ọgbọ́n, òye àti ìjáfáfá àwọn olùṣàwòṣe wọn. A retí pé Vivos Ètò Iṣẹ́ Abẹ Ojú yóò jẹ́ ohun ìmúṣẹ̀dá tí a yìn gidigidi, tó ń gbé ìtẹ̀sí kalẹ̀ tó sì jẹ́ ìrántí tó ń mú iye tí a kò rí rí wá. Àwòṣe tó borí Àmì-ẹ̀yẹ Wúrà A' Design Award yìí jẹ́ iṣẹ́ àkànṣe tó yani lẹ́nu tí a bọ̀wọ̀ fún tó ṣe anfàní gidigidi tó sì ń tì ààlà iṣẹ́ ọnà, sáyẹ́ǹsì, àwòṣe àti ìmọ̀-ẹ̀rọ síwájú. Vivos Ètò Iṣẹ́ Abẹ Ojú ń dá ìmọ̀lára ìfẹ́ tó lágbára sílẹ̀, ń jí ìtara, ń gbé ìṣẹ̀dá lárugẹ tó sì ń fà wá mọ́ra.

Lẹ́yìn Àpẹrẹ Náà

Àkójọ Ìròyìn

Àwọn ẹ̀tọ́, àwọn ọmọ ẹgbẹ́ àti àlàyé ìmọ̀ ẹ̀rọ tí olùṣàpẹrẹ pèsè.

Àwọn Ohun Àkànṣe
Vivos is the only ophthalmic surgery system that grows with clinical needs. Core for cataract. Nova adds vitrectomy. Plus adds laser. One platform. One interface. One training investment. Independent usability validation confirmed 92 percent user satisfaction among first time users. Illuminated connection sockets were rated positively by all study participants. Premium materials and restrained detailing give the device a likeable presence without the visual noise typical of the category.
Ìwọ̀n àti Àpò
Display: 24 inch capacitive touchscreen. Vitrectomy: up to 40000 cuts per min. Vacuum: up to 700 mmHg, highest in category. Phacoemulsification: 53 kHz piezoelectric. IOP: active real-time (VIVOS Balance). Endolaser: 532 nm. Illumination: SOLEA LED, 16.9M colours, 2 ports, Retina Protection Mode. CE pending, submitted Feb 2026. ISO 13485 2016.
Àwọn Àkọlé
Ophthalmic Surgery System, Medical Device Design, Phacoemulsification, Vitrectomy, Modular Medical Platform, Surgical Ergonomics, Workflow Design, German Medical Engineering, Usability Validation, Premium Medical Aesthetics
Ìmọ̀-ẹ̀rọ Ìṣelọ́pọ̀
Medical-grade polycarbonate housing, antimicrobial surface coating rated for over 10,000 disinfection cycles. Piezoelectric phacoemulsification at 53 kHz with beveled-up probe geometry for optimised fluidics. Pneumatic vitrectomy probe up to 40,000 cuts/min. IEC 60601-1 compliant. Modular quick-change cassette - single or multi-patient - tool-free exchange. Compatible with older phaco handpieces, protecting prior investment. Individually assembled in Heidelberg. ISO 13485:2016, IEC 62366-1, IEC 60601-1, CE pending
Ìpèníjà Àpèsè
The central challenge was integrating six surgical functions, historically distributed across two to three separate devices, into a single platform without increasing cognitive load. Internally, decades of segmented product architecture and a 75-year heritage required rethinking established engineering logic. Externally, MDR regulations, IEC 62366 1 usability standards and strict OR hygiene constraints limited design freedom. Maintaining identical UX across Core, Nova and Plus while ensuring durability for thousands of cleaning cycles demanded systemic redesign rather than incremental improvement.
Ìwádìí
Usability research was conducted. Objective: reduce cognitive load without limiting clinical capability. Methodology: iterative co-design workshops with surgeons, Geuder teams and engineering, followed by independent summative validation per IEC 62366-1. Data collection included usability testing and task-based evaluations. Participants: 13 first-time users at RWTH Aachen University, 2026. Results: 91.7% satisfaction, no unacceptable residual risks. Insights validated the workflow UI, surgeon profiles and illuminated sockets, contributing to greater efficiency, improved patient safety and long-term system adoption in clinical practice.
Ìmísí
Ophthalmic surgery is precise. Why should its devices remain fragmented, complex and visually uninspiring. Anterior and posterior procedures require separate investments, training and ecosystems not because clinical need requires it but because no manufacturer redesigned the architecture around the surgeon. Geuder AG with seventy five years of ophthalmic expertise asked what if one platform could grow without hardware replacement. Validated by independent study and unique in its modular upgrade logic.
Àkókò Iṣẹ́ Àkànṣe
The project was developed in Heidelberg, Germany by Geuder AG. Development spanned multiple months with iterative design and engineering phases conducted in close collaboration with ophthalmic surgeons and operating room nursing staff. Summative usability validation was performed at RWTH Aachen University in early 2026. CE Mark application was submitted on 27 February 2026. Public market launch is scheduled for June 2026.
Ìlànà Ìṣiṣẹ́
Before each procedure, the surgeon selects a personal profile, preloading preferred settings and pedal sensitivity. A three-column touchscreen maps each surgical step as a visual sequence. Colour-coded modules allow instant identification in a darkened theatre. Illuminated sockets guide instrument connection by touch. The foot pedal, with individually adjustable actuation force, controls fluid flow and laser hands-free. Eye pressure is monitored and adjusted in real time.
Àwọn Ìwé-ẹ̀rí Ohun-Ìmọ̀
Design copyright: Geuder AG, 2026. Patent application pending. All rights reserved.
Àwọn Ọmọ Ẹgbẹ́
Collaboration between Geuder AG's Engineering, Quality Management, Regulatory Affairs, Product Management, Service, Application, Development, and Sales departments.
Ìfọwọ́sí Àwòrán
Photography Geuder AG, 2026

Oníṣọwọ́

Ṣàwárí Ju Designers.org Lọ

Ṣàwárí àwọn ọjà, iṣẹ́ àti àǹfààní láti ọ̀dọ̀ àwọn alábàáṣe ìpolówó wa.

Àpèsè Dídára Tọ́sí Ìmọ̀yìn Ńlá

A' Design Award jẹ́ àmì ẹ̀yẹ àgbáyé tí àwọn onídàjọ́ ń fúnni fún àpèsè dídára. Kópa nínú A' Design Award láti ní àǹfààní láti gba ìmọ̀yìn tí o tọ́sí, gba òkìkí, ọlá àti ìpolówó fún iṣẹ́ rẹ. Yan iṣẹ́ rẹ fún A' Design Award kí o sì dije fún ẹ̀bùn A' Design Prize tó gbajúmọ̀.

Yan