Ihe emepụtara bụ Tianliao Ọlụlụ Ọkụ nke Suiadr bụ onye meriri a na-asọpụrụ nke ukwuu nke 2021 Ihe Nrite A' Design Award nke Igwe na Udi Asọmpi Nhazi Ụlọ Owu, Ụlọ na Ihe Owuwu.
IgweỤlọ Owu· 2021
Tianliao Ọlụlụ Ọkụ
nke Suiadr
Onye Ahịa: The Institute of Architectural Design and Research, Shenzhen University
Onye Meriri Ihe Nrite A' Design Award nke Igwe na Udi Ụlọ Owu
Onye Meriri Onyinye A Kwadoro
Nyochaa Ọnọdụ Onyinye maka #117138Nhazi a
Maka Tianliao Ọlụlụ Ọkụ
Tianliao bụ ụlọ ọrụ mgbanwuru ọkụ dị na Guangming District, Shenzhen, China. Ụlọ a na-agbaso usoro mmezu etiti, ma jikọta ụlọ ọrụ nzuko nke nwere ntọala atọ na ụlọ ọzụzụ toworu ogologo nke nwere ntọala asaa. Ohere ala niile nke ụlọ a bụ mita kwadoro 5,039.5, ebe mita kwadoro 3,985 dị n'elu ala, na ọnụ ọgụgụ ohere ala bụ 0.97. Ntọala ime ụlọ ka ewuliri elu karịa ụzọ obodo iji gbochie mmiri ozuzo ịbanye n'ime ya. Ohere mepere emepe ka etinyere na ntọala ndị dị ala, ka ọzụzụ kwa ụbọchị ghara inwe nnọchibido. Ubi ihe ndoro-ndoro dị n'ọtụtụ ebe n'ime saịtị ahụ.
Nkwanye Ugwu
Maka Ihe Nrite A' Design Award nke Igwe
Tianliao Ọlụlụ Ọkụ meriri A' Design Award nke Igwe, nnabata dị ugwu e nyere design ndị dị mma nke na-emezu ihe ndị a chọrọ n'ọrụ na ụlọ ọrụ nke a na-atụ anya n'ihe e kere eke ndị e mere nke ọma. Ndị meriri na Igwe na-egosi nka buru ibu, ọkachamara dị elu, nghọta ọkachamara na ikike imepụta nke ndị kere ha. A na-atụ anya na Tianliao Ọlụlụ Ọkụ ga-abụ ihe e kere eke a na-asọpụrụ nke ukwuu, a na-eto na a hụrụ n'anya nke bụ ihe bara uru ma dị ọhụrụ. Design a meriri A' Design Award nke Igwe na-ejikọta ụzọ kacha mma nke ụlọ ọrụ ma nwee àgwà teknụzụ kwesịrị ekwesị jikọtara na ihe ọmụma na talent. A na-asọpụrụ Tianliao Ọlụlụ Ọkụ maka nlezianya ya ma e mere ya ka ọ nye mmeziwanye ndụ nke na-enyere aka ime ka ụwa bụrụ ebe ka mma.
N'azụ Nhazi a
Ngwugwu Mgbasa Ozi
Nkwurịta okwu, ndị otu na nkọwa teknụzụ nke onye nhazi nyere.
- Àgwà Pụrụ Iche
- It's a new fire station with a centralized layout. The vertical design makes the station almost as tall as the Huanguang Road. The internal elevation of the station is higher than that of the municipal road, preventing rainwater from flowing into the inside. The layout meets the requirements of setback, sunshine and fire prevention, etc. The pedestrian entrance and exit are at the southwest side. The open areas are mainly at 1F and the mezzanine, making no influence on firemen's daily training.
- Nha & Mkpuchi
- Its gross floor area is 5,039.5 sqm with 3,985 sqm above the ground. It has a 3-story office building and a 7-story training tower. The floor area ratio is 0.97. The exterior windows adopt LOW-E energy-efficient glass and thermal mortar. The roofing is paved with 50mm extruded polystyrene boards for thermal insulation. The septic tank and oil separator tank adopt integrated equipment like glass steel. The energy-saving water heating system uses solar power and air force heat pump.
- Mkpado
- Fire station, centralized layout, standardization, setback, multi-layer public building, infrastructure, The Institute of Architectural Design and Research, Shenzhen University, Z&Z STUDIO
- Teknụzụ Mmepụta
- 1. The exterior windows adopt LOW-E energy-efficient glass and thermal mortar. The roofing is paved with 50mm extruded polystyrene boards for thermal insulation.
2. The project mainly uses reinforced concrete frame structure and the base adopts independent column-shaped and bar-shaped waterproof slabs. The roof uses cast-in-situ reinforced concrete slab system with main and secondary beams. Secondary beams are set properly to reduce the plane size of slab avoiding too much material waste. - Ịma Aka Imepụta
- Building setback: Due to the limited land, it was possible to set back building in accordance with the official requirements. After several times of negotiation with the planning bureau, the design team reached a reasonable bargain: the plot is set back 2.3m on the east, 6.05m on the south, 2.3m on the west and 1.8m on the north. In this way, the fire station and sports fields were reasonably arranged within the limited land.
- Nchọpụta
- The design must follow the research results of "the 2014 Shenzhen Fire Station Standardization Design Workshop". It shall establish the construction standards of Shenzhen fire stations. The experience of it can also provide reference for domestic fire stations. The design should satisfy basic needs, consider the possibility of the profession development, and embody the considerations of openness and cultural promotion of fire control. It has won a second prize awarded by SUIADR in 2020.
- Mkpali
- Located in Guangming District, Shenzhen, the project occupies the land of 4,099.16 m2, with the planned Huanguang Road on the west, the planned Nantian Road on the north, Nangen Road on the south and Mobi Antenna Technology (Shenzhen) Co., Ltd. on the east. As a first-class fire house, its gross floor area is 5,039.5 m2 with 3,985 m2 above the ground and 1,054.5 m2 underground. It consists of a three-story office building and a seven-story training tower.
- Oge Ọrụ
- Starting time: November 10, 2016
Completion time : July 20, 2020
Location: Guangming District, Shenzhen - Usoro Ọrụ
- The parking garage for fire trucks faces the street. The visiting entrance and exit is at the southwest side of the plot. The open areas are at 1F and 2F, the foyer and canteen at 1F. Firemen's preparation rooms are on 2F with a bathroom and a shower room on the west. 3F houses offices and auxiliary rooms and the basement has an emergency storeroom and equipment room. Gardens are set at many places, enriching firemen’s life.
- Ndị Otu
- Zhong Zhong, Zhong Botao, Wang Min, Zhong Haihuan、Zeng Yusheng、Su Xiaoyue、Deng Rixing
Liu Mu、Yong Yong、An Huijuan、Zhou Jie、Cao Jiying、Xiong Feng、He Xiaoming、Wang Wei
Ye Zhien、Wu Zhirong - Asụsụ Foto
- Tian Tengfei
Nkwado
Nyochaa Karịa Designers.org
Chọpụta ngwaahịa, ọrụ na ohere sitere n'aka ndị mmekọ mgbasa ozi anyị.
Ihe Ndị Ọzọ Ị Ga-Achọpụta
Nhazi Ndị Yiri Ya
Chọpụta nhazi ndị ọzọ nwetara onyinye sitere n'otu udi, ahọpụtara site na ịdị mma.